West Chester, PA, United States
Synthes (USA) Products LLC recalls
20 recalls recorded since 2018, most recently on 25 February 2026. 9 are listed as ongoing. Status and classification are as published by the FDA.
Recalls20
Ongoing (FDA)9
Terminated or completed11
Class I (FDA)0
Ongoing Class II Medical devices
- Recall started
- 25 February 2026
- Reason
- A full lot swap between VOLT Locking Screw Tap 03.424.124 lot 68900P9 and Cortical Screw Tap 03.424.126 lot 68982P8, resulting in the bones taps having an incorrect thread.
- Distribution
- US Nationwide distribution in the states of AR, AZ, CA, CO, FL, IN, LA, MD, MN, NC, NJ, OH, OK, OR, PA, TN, TX, UT, VA, WA, WI.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1702-2026, Z-1703-2026
- 2.4 VOLT TAP LOCKING SCREW TAP TO 90MM. Part Number: 03.424.124-US.
- 2.4 VOLT(TM) TAP CORTEX SCREW TO 90MM. Part Number: 03.424.126-US.
Ongoing Class II Medical devices
- Recall started
- 26 September 2025
- Reason
- Although the etched length on the screw is correct, the length marked on the external packaging is incorrect. Specifically, 42mm screws were packaged and labeled as 46mm, while 46mm screws were packaged and labeled as 42mm.
- Distribution
- Worldwide - US Nationwide distribution in the states of AL, AR, AZ, CA, FL, GA, IA, IL, IN, KS, KY, LA, MA, MD, MN, MO, MS, NJ, NM, NY, OH, TN, TX and the country of Canada.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-0228-2026, Z-0229-2026
- LOW PROF LCKNG SCREW, F/IM NAIL 5.0MM / L, 46MM / XL25/ STER. Product Code: 04.045.346TS. Used in RFN-ADVANCEDTM Retrograde Femoral Nailing (RFNA) System and the Tibial Nail Advanced System.
- LOW PROF LCKNG SCREW, F/IM NAIL 5.0MM / L, 42MM / XL25/ STER. Product Code: 04.045.342TS. Used in RFN-ADVANCEDTM Retrograde Femoral Nailing (RFNA) System and the Tibial Nail Advanced System.
Ongoing Class II Medical devices
- Recall started
- 25 April 2024
- Reason
- Stardrive Screwdrivers manufactured without a 5-degree relief cut around the tip and will not engage with their respective 1.3mm and 1.5mm screws, may result in surgical delay
- Distribution
- Worldwide distribution - US Nationwide and the country of Canada.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-1916-2024
- STARDRIVE SCRWDRVR SHFT/T4 50MM/SELF-RETAINING/HXC-Intended for tightening, loosening, or removing of screw implants during orthopaedic surgery. Part Number: 03.130.010
Ongoing Class II Medical devices
- Recall started
- 24 January 2024
- Reason
- Products not sterilized, sterility cannot be confirmed
- Distribution
- Worldwide distribution - US Nationwide and the countries of Argentina, Austria, Australia, Belgium, Canada, Czech Republic, Germany, Spain, Finland, France, United Kingdom, Ireland, South Korea, Kuwait, Mexico, Netherlands, Slovakia, Taiwan, South Africa.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1242-2024, Z-1238-2024, Z-1234-2024, Z-1239-2024, Z-1235-2024, Z-1241-2024, Z-1236-2024, Z-1237-2024, Z-1240-2024
- Opal, Intervertebral Cage, 10x32mm, h 11mm, Revolvable-Indicated for degenerative spine disease Part Number: 08.803.231S
- RAPIDSORB IPS Battery Pack, Sterile-Intended for use in non-load bearing fracture repair and reconstructive procedures of the craniofacial skeleton (excluding the upper and lower jaw) in pediatric and adult populations.
- 13 mm Titanium Hindfoot Arthrodesis Cannulated Nails EX, sterile -Intended to facilitate tibiotalocalcaneal arthrodesis to treat severe foot/ankle deformity, arthritis, instability, and skeletal defects after tumor resec
- TFNA Femoral Nail 9mm, right, 130¿, L 235mm-Intended for temporary fixation and stabilization of proximal femur fractures. Part Number: 04.037.944S
- 1.5MM Drill Bit/QC/85MM Sterile-surgical, orthopedic, pneumatic powered & accessory/attachment Part Number: 310.15S
- VA-LCP Clavicle Plate 2.7, shaft, CS1, right-Intended for fixation of clavicle bone fragments. Part Number: 02.112.621S
- 2.5MM DRILL BIT/QC/GOLD/110MM STERILE-surgical, orthopedic, pneumatic powered & accessory/attachment Product Code: 310.25S
- RIA Tube Assembly, minimum 520 mm length, sterile- intended for use in adults and adolescents (12-21 years) to clear the medullary canal of bone marrow and debris and to effectively size the medullary canal for the acce
- and 1 more product lines
Ongoing Class II Medical devices
- Recall started
- 1 February 2023
- Reason
- TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length
- Distribution
- Worldwide - US Nationwide distribution in the states of MS, OR, TX and the countries of Canada, Japan.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1246-2023, Z-1247-2023, Z-1248-2023
- TFN-Advanced Femoral Nail 12MM/125 DEG TI CANN TFNA 200MM STERILE. Intended for temporary fixation and stabilization of proximal femur fractures. Part Number: 04.037.213S
- TFN-Advanced Femoral Nail 12MM/125 DEG TI CANN TFNA 170MM - STERILE. Intended for temporary fixation and stabilization of proximal femur fractures. Part Number: 04.037.212S
- TFN-Advanced Femoral Nail 12MM/130 DEG TI CANN TFNA 170MM STERILE. Intended for temporary fixation and stabilization of proximal femur fractures Part Number: 04.037.242S
Ongoing Class II Medical devices
- Recall started
- 27 September 2022
- Reason
- The subject products are being recalled because they contain the incorrect size drill guide and will not prepare the bone correctly for the size of the implant included in the sterile kit. If the incorrect drill guide is used, there is potential for bone damage due to incorrectly placed drill holes for the implant included in the kit.
- Distribution
- US Nationwide distribution.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-0100-2023, Z-0101-2023, Z-0098-2023, Z-0099-2023
- SPEED 9X10X10mm Continuous Compression Implant, Product No. SE-0910
- DePuy Synthes Hammertoe Continuous Compression Implants, Product No. 46.239.001
- SPEEDSHIFT20x20x20 Offset 10mm Implant Drill Kit, Product No. SE-2020-10. Used with DePuy Synthes SPEEDSHIFT Continuous Compression Staple Implants for bone fixation and management of fracture and reconstructive surgery
- SPEED 15X12X12mm Continuous Compression Implant, Product No. SE-1512
Ongoing Class II Medical devices
- Recall started
- 30 August 2022
- Reason
- Drill Pin (drill bit) is not compatible with the Drill Template included in the kit due to a packaging error, result in a surgical delay and may cause soft tissue damage if a larger incision is required to accommodate an alternative form of fixation. Additionally, there is a potential for adverse tissue reaction if the surgeon attempts to use the guide regardless of tight fit and plastic debris is created and ends up in the wound
- Distribution
- US Nationwide distribution.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0008-2023
- Hammertoe Continuous Compression Implant (CCI) Kit Part Number: 46.239.001
Ongoing Class II Medical devices
- Recall started
- 7 April 2022
- Reason
- DePuy Synthes Radial Head Replacement System Contraindications added to Electronic Instructions for Use (e-IFU): Absolute contraindications include: Infection, sepsis, osteomyelitis.
- Distribution
- US Nationwide distribution.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-1072-2022
- Radial Head Replacement System Implant is a one-piece, stemmed radial head replacement. The radial head is available in diameters of 19, 22 and 25mm. The radial stems range from 5.5 to 8.5mm in diameter and from 21 24mm
Ongoing Class II Medical devices
- Recall started
- 22 December 2021
- Reason
- Top cap may loosen and detach if the Universal Chuck becomes jammed and the user attempts to manually free the device, internal ball bearings may fall out onto the surgical field and cause surgical delay or, and if not recovered, adverse tissue reaction and infection.
- Distribution
- US Nationwide distribution.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0634-2022
- Universal Chuck-The Universal Chuck is an Instrument Handle provided as an alternative instrument available for use in the TN-ADVANCED" Tibial Nailing System (TNA), TFN-ADVANCED" Proximal Femoral Nailing System (TFNA), R
Terminated Class II Medical devices
- Recall started
- 19 November 2020
- Terminated
- 1 July 2022
- Reason
- RIA 2 reamer head breakage exceeds the expected occurrence rate resulting in adverse tissue reaction, soft tissue damage, and/or bone damage, when the recommended surgical techniques are not followed
- Distribution
- Nationwide Foreign:countries: United Arab Emirates, Austria, Australia, Belgium, Switzerland, China, Czech Republic, Germany, Spain, United Kingdom, Ireland, Israel, Italy, Singapore,
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-0575-2021, Z-0574-2021, Z-0581-2021, Z-0577-2021, Z-0583-2021, Z-0584-2021, Z-0576-2021, Z-0580-2021, Z-0573-2021, Z-0572-2021, Z-0571-2021, Z-0578-2021 and 5 more
- DePuy Synthes 12.0MM REAMER HEAD FOR RIA 2 STERILE -Orthopedic manual surgical instrument Part Code: 03.404.020S
- DePuy Synthes 11.5MM REAMER HEAD FOR RIA 2 STERILE-Orthopedic manual surgical instrument Part Code: 03.404.019S
- DePuy Synthes 15.0MM REAMER HEAD FOR RIA 2 STERILE -Orthopedic manual surgical instrument Part Code: 03.404.026S
- DePuy Synthes 13.0MM REAMER HEAD FOR RIA 2 STERILE-Orthopedic manual surgical instrument Part Code: 03.404.022S
- DePuy Synthes 16.0MM REAMER HEAD FOR RIA 2 STERILE--Orthopedic manual surgical instrument Part Code: 03.404.028S
- DePuy Synthes 16.5MM REAMER HEAD FOR RIA 2 STERILE-Orthopedic manual surgical instrument Part Code: 03.404.029S
- DePuy Synthes 12.5MM REAMER HEAD FOR RIA 2 STERILE -Orthopedic manual surgical instrument Part Code: 03.404.021S
- DePuy Synthes 14.5MM REAMER HEAD FOR RIA 2 STERILE-Orthopedic manual surgical instrument Part Code: 03.404.025S
- and 9 more product lines
Terminated Class III Medical devices
- Recall started
- 21 September 2020
- Terminated
- 30 December 2022
- Reason
- Incorrectly Labeled 'general medical device,' printed on the statutory label of the SYNMESH CAGE SYSTEM instead of 'specially controlled medical device"
- Distribution
- International distribution the country of Japan Only.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-0412-2021, Z-0414-2021, Z-0407-2021, Z-0415-2021, Z-0410-2021, Z-0417-2021, Z-0404-2021, Z-0405-2021, Z-0408-2021, Z-0406-2021, Z-0409-2021, Z-0411-2021 and 3 more
- END RING 17MM X 22MM LATERAL OR ANTERIOR/5 DEG (TI) Product Number: 495.394 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints a
- END RING 22MM X 28MM LATERAL OR ANTERIOR/5 DEG (TI) Product Number: 495-398 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints a
- SYNMESH¿ 22MM X 28MM 88MM HEIGHT (TI) Product Number: 495.379 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints and heights ena
- STANDARD RING 17MM X 22MM (TI) Product Number: 495-405 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints and heights enable the s
- END RING 15MM DIA/0 DEG (TI) Product Number: 495.386 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints and heights enable the su
- 3.0MM LOCKING SCREW LOW PROFILE (TI) Product Number: 495-491 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints and heights enab
- SYNMESH 12MM DIA 88MM HEIGHT (TI) Product Number: 495.357 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints and heights enable
- SYNMESH 15MM DIA 88MM HEIGHT (TI) Product Number: 495.366 - Product Usage: is a vertebral body replacement device for the cervical, thoracic and lumbar spine. Titanium implants in various footprints and heights enable
- and 7 more product lines
Terminated Class II Medical devices
- Recall started
- 21 July 2020
- Terminated
- 18 February 2022
- Reason
- May have one or more dimensional features out of tolerance includes: thread pitch diameter depth, thread minor diameter depth, plate thickness and end length out of tolerance that can potentially result in a reduced locking strength of an LCP screw
- Distribution
- US Nationwide distribution.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-2816-2020
- DePuy Synthes Trauma LCP One-Third Tubular Plate with Collar 8 Holes / 93mm - Product Usage: intended for fixation of fractures, osteotomies and non-unions of clavicle, scapula, olecranon, humerus, radius, ulna, pelvis,
Terminated Class II Medical devices
- Recall started
- 16 September 2019
- Terminated
- 24 April 2020
- Reason
- The subject product measures 4.0mm in diameter instead of 3.5mm.
- Distribution
- Distributed to NJ.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0223-2020
- Synapse System 3.5mm TI Cancellous Polyaxial Screws, Part No. 04.615.026 for use in spinal surgery
Terminated Class II Medical devices
- Recall started
- 5 September 2019
- Terminated
- 23 June 2020
- Reason
- Modified outside of approved manufacturing process
- Distribution
- AR
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0349-2020
- MODIFIED INSTRUMENTS: Trial Spacer 7mm with T-Handle Trial Spacer 8mm with T-Handle Trial Spacer 9mm with T-Handle Trial Spacer 10mm with T-Handle Trial Spacer 11mm with T-Handle Trial Spacer 12mm with T-Handle Tr
Terminated Class II Medical devices
- Recall started
- 12 September 2018
- Terminated
- 10 April 2020
- Reason
- The product inside the package does not match the label. The product was labeled as long thread screws that have a 6mm thread length but were actually short thread screws with a 4mm thread length.
- Distribution
- US Distribution to the following states: AR, AZ, FL, IL, NM, OH, and TX.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0238-2019
- 3.0mm Headless Compression Screw, Long Thread 18mm, Part Number 04.226.118 DePuy Synthes 3.0mm Headless Compression Screws are intended for fixation of intra-articular and extra-articular fractures and nonunions of s
Terminated Class II Medical devices
- Recall started
- 4 May 2018
- Terminated
- 21 October 2019
- Reason
- The adapter may demonstrate a degradation of function as the final products were assembled with ball bearings of high carbon content that is likely to rust prematurely.
- Distribution
- USA (nationwide) Distribution to the states of : AK, CA, FL, ID, IN, KS, KY, LA, MD, MI, MT, NC, NJ, NY, OH, OK, PA, SD, TN, TX, UT, WI, and WV.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-1916-2018
- Synthes Torque Limiting Handle, Part Number 03.231.013 This device is used in systems indicated for fracture fixation.
Terminated Class II Medical devices
- Recall started
- 2 April 2018
- Terminated
- 16 October 2019
- Reason
- There is a potential for microspores to form on the hollow handle of the Sciatic Nerve Retractor. The pores may increase in size, allowing fluid to enter the hollow handle.
- Distribution
- US Nationwide and Canada
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1758-2018, Z-1759-2018
- Retractor f/Sciatic Nerve; Part number: 03.100.013; UDI: 10886982070623
- Retractor f/Sciatic Nerve Long; Part number: 03.100.014; UDI: 10886982070630
Terminated Class II Medical devices
- Recall started
- 5 March 2018
- Terminated
- 28 February 2020
- Reason
- Affected screw gauges incorrectly measure screws 5.41mm shorter than the actual overall screw length.
- Distribution
- Distributed to accounts in CA, IL, IN, KS, LA, MD, NC, NE, NJ, OR, TX, and VA. Foreign distribution to Canada.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-2246-2018, Z-2247-2018, Z-2245-2018
- Part no. 690.379, Graphic Case F/6.5mm Cannulated Screw Set
- Part no. 690.380, Graphic Case F/7.3mm Cannulated Screw Set
- Part no. 690.375, Graphic Case F/6.5mm & 7.3mm Combined Cannulated Screw Set
Terminated Class II Medical devices
- Recall started
- 26 July 2017
- Terminated
- 10 September 2018
- Reason
- Possible lack of product sterility due to potential gaps/channeling in the seal of the package.
- Distribution
- Worldwide Distribution: US (Nationwide) to states of: AK, AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, the District of Columbia, including Puerto R
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-0901-2018, Z-0907-2018, Z-0903-2018, Z-0906-2018, Z-0904-2018, Z-0905-2018, Z-0902-2018
- 2.5 mm Reaming Rod, Ball tip, 950 mm, sterile, Part Number: 351.706S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
- Light Clip for Oracle Retractor, sterile, Part Number: 03.809.925S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
- 2.5 mm Reaming Rod, Ball tip, 1150 mm, sterile, Part Number: 351.708S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
- 2.5 mm Titanium Calibrated Reaming Rod, 850 mm, Part Number: 359.083S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
- 3.0 mm Reaming Rod, with straight ball tip, 950 mm, sterile, Part Number: 351.76S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
- 2.5 mm Guide Rod, with smooth tip, 950 mm, sterile, Part Number: 355.042S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
- 2.5 mm Reaming Rod, Ball tip with extension, 950 mm, sterile, Part Number: 351.707S Reaming Rods are intended for guiding of reamers during orthopedic surgery.
Terminated Class II Medical devices
- Recall started
- 21 July 2017
- Terminated
- 10 July 2018
- Reason
- The locking mechanism and protective cap were missing from the sterile packed nails of the affected lot.
- Distribution
- TX, GA, PA, UT and Canada
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0604-2018
- 11MM/130 Degree Titanium Trochanteric Fixation Nail 380MM/Right, Sterile
A terminated FDA recall means the FDA has determined that all reasonable efforts to remove or correct the product have been made. What statuses mean.