Stryker Neurovascular recalls
15 recalls recorded since 2018, most recently on 6 April 2026. 6 are listed as ongoing. Status and classification are as published by the FDA.
Recalls15
Ongoing (FDA)6
Terminated or completed9
Class I (FDA)1
Ongoing Class II Medical devices
- Recall started
- 6 April 2026
- Reason
- Embolization coil detachment system devices may experience premature battery drain causing devices to: 1) Not power on; 2) Power on with faint audible and visual indicators; 3) Be unable to detach a coil as intended, which may necessitate medical intervention if the procedure must be completed with an alternative technique.
- Distribution
- Worldwide - US Nationwide distribution including in the states of PA, AZ, FL, CA, IL, AK, NY, MI, NJ, WI, SD, KY, AR, TX, AL, TN, MO, MA, IN, NE, WV, MT, CT, NC, VA, NV, CO, DC, DE, OH, ME, GA, WA, SC, GU, MN, OK, NH, MD, ND, UT, HI, OR, LA, MS, KS, NM, ID, IA, VT and the countries of ARGENTINA, AUS
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-2552-2026
- INZONE DETACHMENT SYSTEM, REF: M00345100950
Ongoing Class II Medical devices
- Recall started
- 30 August 2024
- Reason
- Stryker Neurovascular has observed that devices with Out of United States (OUS) approved Instructions for Use (IFU) and Packaging Labels (pouch and carton), different configurations, have been erroneously distributed to customers in the US.
- Distribution
- U.S. Nationwide distribution in the states of CA and VA.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0021-2025
- The Trevo Trak 21 Microcatheter is a single-lumen, braided shaft, variable stiffness catheter with radiopaque marker(s) on the distal end and a luer hub on the proximal end. The catheter shaft has a hydrophilic coating o
Ongoing Class II Medical devices
- Recall started
- 23 April 2024
- Reason
- Neurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
- Distribution
- Worldwide - US Nationwide distribution including in the states of MN, PA, IL, AK, NY, CA, MI, WI, TX, AZ, FL, KY, MA, IN, NE, MT, CT, NJ, TN, VA, AL, CO, DE, OH, UT, NC, ME, GA, SC, GU, WA, MO, OR, DC, OK, LA, MD, ID, NH, SD, NV, RI, ND, HI, MS, AR, IA, NM, VT, KS and the countries of Australia, Aus
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1903-2024, Z-1906-2024, Z-1909-2024, Z-1908-2024, Z-1905-2024, Z-1902-2024, Z-1907-2024, Z-1904-2024
- Trevo ProVue, Catalog: 90184
- Trevo Trak 21 Microcatheter, Catalog: 90338
- Synchro .014"guide wire, 35 cm tip, Catalog: M00313010 Synchro .014 guide wire, 300 cm length, Catalog: M00313310 SYNCHRO .010 WIRE SOFT STRAIGHT 200cm, Catalog: M00316310 SYNCHRO .010 WIRE SOFT STRAIGHT 300cm, Catalo
- DAC 044 115cm, Catalog: 90760
- Trevo NXT ProVue 3 x 32, US, Catalog: 90312 Kits: TREVO NXT 3X32+TRAK21 2-PACK - CE, Catalog: 91412 TREVO NXT 4X28+TRAK21 2-PACK - CE, Catalog: 91413 TREVO NXT 4X41+TRAK21 2-PACK - CE, Catalog: 91414 TREVO NXT 6X3
- Trevo XP ProVue Retriever 4 x 20, Catalog: 90182 Trevo XP ProVue Retriever 3 x 20, Catalog: 90183 Trevo XP ProVue Retriever 4 x 30, Catalog: 90185 Trevo XP ProVue Retriever 6 x 25, Catalog: 90186 Kits: TREVO XP 3
- FlowGate2 8F x 85cm, Catalog: 90485 FlowGate2 8F x 95cm, Catalog: 90495
- Trevo Pro 14 Microcatheter, Catalog: 90231; Trevo Pro 18 Microcatheter, Catalog: 90238
Ongoing Class II Medical devices
- Recall started
- 18 April 2024
- Reason
- Stryker Neurovascular has observed an increased frequency of PTFE coating damage occurring on the Synchro Guidewires that may be caused by the practice of backloading the guidewire through the optional introducer accessory. This issue is limited to certain lots of the Synchro Guidewire that contain an older version of the introducer accessory. Due to variation in the manufacturing process of the supplier of the introducer accessory, certain lots of introducers have sharper than intended edges that can peel off the PTFE coating when physicians use a technique known as backloading. Users with impacted product in their inventory are cautioned not to use this backloading technique.
- Distribution
- Worldwide - US Nationwide distribution including in the states of TX, NY, MD, CA, KY, WI, OR, NE, SC, MA, MO, CT, ID, PA, TN, FL, NC, AL, IA, OK, VA, IL, OH, NH, MN, ND, KS, NJ, WV, IN, GA, HI, AR, UT, LA, MI, WA, NV, CO, AZ, DC, VT, ME, DE, AK, WY, MT, NM, SD, MS, RI, GU and the countries of ARGENT
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1941-2024, Z-1940-2024, Z-1939-2024
- The Synchro2 Guidewires are a steerable guidewire family with a shapeable tip and are available in straight and pre-shaped versions. The outside diameters of the guidewires are 0.014 in. The guidewires are compatible wit
- The Synchro SELECT Guidewires are a steerable guidewire family with a shapeable tip and are available in straight and pre-shaped versions. The outside diameters of the guidewires are 0.014in. The guidewires are compati
- The Synchro Neuro Guidewires are a steerable guidewire family with a shapeable tip. The outside diameter of the Synchro 10 guidewire is 0.010in. The outside diameter of the Syncrho 14 guidewire is 0.014in. The guidewires
Ongoing Class II Medical devices
- Recall started
- 3 April 2024
- Reason
- Stryker Neurovascular is recalling their DAC- Distal Access Catheter -038 136cm, a Distal Access Catheter by removal. The reason for the recall is: the DAC Lot #0000486382 was released with out-of-specification endotoxin results.
- Distribution
- US Nationwide distribution in the states of TX, FL, NJ, CO, LA, NC, AL, PA, MI, MS, SC, IL.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-1740-2024
- The Distal Access Catheter is a single-lumen, braided shaft, variable stiffness catheter with radiopaque marker on the distal end and a luer hub on the proximal end. The catheter shaft has a hydrophilic coating to reduce
Ongoing Class II Medical devices
- Recall started
- 3 June 2022
- Reason
- Microcatheter product label on the carton is missing the microcatheter product drawing/illustration.
- Distribution
- Worldwide distribution - US Nationwide distribution in the states of CA, OR, PA, NY, DC, IL, WA, NH, NJ, OK, FL, AZ, AL, GA, TX, WI, VA and the countries of DE, IT, AT.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-1386-2022
- Trevo Trak 21 Microcatheter, REF: 90338. TREVO NXT 3X32+TRAK21 2-PACK - CE, REF: 91412; TREVO NXT 4X28+TRAK21 2-PACK - CE, REF: 91413; TREVO NXT 4X41+TRAK21 2-PACK - CE, REF: 91414; TREVO NXT 6X37+TRAK21 2-PACK - C
Terminated Class I Medical devices
- Recall started
- 21 September 2020
- Terminated
- 1 April 2024
- Reason
- Increase in fracture complaints of the flexible, tapered core wire, resulting in stent retriever separation from the core wire during use. The stent retriever can be left behind in the vasculature.
- Distribution
- U.S.: PA, OH, AK, NY, VA, IL, CA, NJ, AL, NV, FL, KY, AR, MA, TX, MI, NC, TN, WI, WA, AZ, OR, GA, VT, UT, DC, MO, IN, OK, NH, LA, HI, DE, SC, MS, RI, MD, SD, KS, ID, CO, CT, IA, NM, WV, MN, GU, NE. Foreign: New Zealand, Argentina, Estonia, Lithuania, Slovenia, Australia, Finland, Luxembourg, Sout
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0114-2021
- Trevo XP ProVue Retriever, REF (Size): 90182 (4MM x 20MM); 90185 (4MM x 30MM); 90186 (6MM x 25MM). Procedure Pack REF: 80052, 93067, 93068, M0032PK42010001, M0033PK42022001, M0033PK43022001, M0033PK62523001, M0032PK4201
Terminated Class II Medical devices
- Recall started
- 18 April 2019
- Terminated
- 27 April 2021
- Reason
- A design related issue can contribute to the device exhibiting brittle behavior. This behavior may result in fractures of the catheter shaft.
- Distribution
- U.S Nationwide Distribution - PA, VA, TX, CA, FL, AR, TN, MI, NY, IL, NC, KY, WV, OH, MO, AZ, GA, WA, VT, DC, SC, NJ, MN, OK, MD, AL, LA, MA, DE, IN, OR, RI, SD, MS, WI, ID, UT, CO, IA, KS, CT, NE, NM
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-1708-2019
- Stryker Neurovascular, AXS Infinity LS Plus Long Sheath, Rx Only, Sterile EO, USA Customer Service 855-91 NEURO (916-3876): a) REF: INC-11196-70, 70cm, b) REF: INC-11196-80, 80cm, c) REF: INC-11196-90, 90cm Produ
Terminated Class II Medical devices
- Recall started
- 10 April 2019
- Terminated
- 25 February 2021
- Reason
- The firm has become aware of a potential problem that their Catheters may break/fracture and/or kink/bend if improperly removed from the packaging/dispenser hoop or during catheter use.
- Distribution
- US Nationwide distribution in the states of PA, FL, CA, IL, WI, AZ, AR, FL, TN, MI, MA, CA, NC, WV, DE, OH, NJ, MO, NY, SC, TX, AL, VA, UT, MD, GA, LA, CO, WA, KY, OK, RI, SD, MS, NE,IA, KS, DC. No US Govt. No Foreign countries.
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-1620-2020, Z-1621-2020
- Stryker Neurovascular, AXS Vecta 71 Aspiration Catheter, Ref. Catalog No. INC-11129-115, Use By 2021-11-29, Rx Only, Sterile/EO, Manufactured For: Stryker Neurovascular 47900 Bayside Parkway, Fremont, CA 94538, UDI: (01)
- Stryker Neurovascular, AXS Vecta 74 Aspiration Catheter, Ref. Catalog No. INC-11597-115, Use By 2021-11-29, Rx Only, Sterile/EO, Manufactured For: Stryker Neurovascular 47900 Bayside Parkway, Fremont, CA 94538, UDI: (01)
Terminated Class II Medical devices
- Recall started
- 13 November 2018
- Terminated
- 3 August 2020
- Reason
- Labeling error; 8F Balloon Guide Catheters have been packaged within 9F Balloon Guide Catheter packaging
- Distribution
- OUS distribution only: CZECH REPUBLIC, ITALIA, Netherlands, Sweden, Germany, Austria, Israel, France, Belgium, Finland, Switzerland, Portugal, Finland
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0065-2020
- Stryker Neurovascular, Merci 9F, 80cm, Balloon Guide Catheter, REF 90077, CE 0459, UPN Product No. 90077, UDI #: (01)00815742000771
Terminated Class II Medical devices
- Recall started
- 8 June 2018
- Terminated
- 28 April 2021
- Reason
- The product labels (pouch and carton) for products contain an incorrect value in millimeters (0.036mm) for the Guidewire Outer Diameter dimension. The inches dimension (0.014in) on the label is correct. The correct values are 0.014in (0.36mm). 0.036mm represents a typographical error.
- Distribution
- Worldwide distributions- U.S. Nationwide including the states of AL, AZ, AR, CA, CO, CT, DC, DE, FL, GA, GU, HI, ID, IL, IN, IA, KS, KY, LA, ME, MD, MA, MI, MN, MS, MO, MT, NE, NV, NH, NJ, NM, NY, NC, ND, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VT, VA, WA, WV, WI, WY. Countries of Austria, Argent
- Initiated
- Voluntary: Firm initiated
- Recall numbers
- Z-0225-2020, Z-0228-2020, Z-0229-2020, Z-0232-2020, Z-0231-2020, Z-0230-2020, Z-0227-2020, Z-0226-2020
- Synchro2, 0.014 in x 200cm, SOFT Guidewire with Hydrophilic Coating, UPN Product No. M00326010 REF 2601, STERILE: EO - Product Usage: product is intended for general intravascular use, including neurovascular and periphe
- Synchro2, 0.014in. x 300cm, SOFT PRE-SHAPED Guidewire with Hydrophilic Coating, UPN Product No. M00326320, REF 2632, STERILE:EO - Product Usage: product is intended for general intravascular use, including neurovascular
- Synchro2, 0.014in x 200cm STANDARD Guidewire with Hydrophilic Coating, UPN Product No. M00326410, REF 2641, STERILE: EO - Product Usage: product is intended for general intravascular use, including neurovascular and peri
- Synchro2, 0.014in x 300cm STANDARD PRE-SHAPED Guidewire with Hydrophilic Coating, UPN Product No. M00326520, REF 2652, STERILE: EO - Product Usage: product is intended for general intravascular use, including neurovascul
- Synchro2, 0.014in x 300cm STANDARD Guidewire with Hydrophilic Coating UPN Product No. M00326510, REF 2651, STERILE:EO - Product Usage: product is intended for general intravascular use, including neurovascular and periph
- Synchro2, 0.014in. x 200cm STANDARD PRE-SHAPED Guidewire with Hydrophilic Coating UPN Product No. M00326420, REF 2642, STERILE: EO - Product Usage: product is intended for general intravascular use, including neurovascul
- Synchro2, 0.014in x 300cm SOFT Guidewire with Hydrophilic Coating , UPN Product No. M00326310, REF 2631, STERILE:EO - Product Usage: product is intended for general intravascular use, including neurovascular and peripher
- Synchro2, 0.014in x 200cm, SOFT PRE-SHAPED Guidewire with Hydrophilic Coating, UPN Product No. M00326110, REF 2611, STERILE: EO - Product Usage: product is intended for general intravascular use, including neurovascular
Terminated Class II Medical devices
- Recall started
- 5 June 2018
- Terminated
- 30 November 2020
- Reason
- Use-related coating damage on delivery catheter shafts of Wingspan delivery catheters were reported
- Distribution
- China
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-3020-2018
- Wingspan Stent System, Rx Only, Sterile EO, Catalog #: M003WE0250090, M003WE0300090, M003WE0350090, M003WE0400090, M003WE0450090, M003WE0250150, M003WE0300150, M003WE0350150, M003WE0400150, M003WE0450150, M003WE0250200
Terminated Class II Medical devices
- Recall started
- 2 May 2018
- Reason
- The AXS Infinity LS Long Sheath Dilator outer diameter (OD) specification was exceeded.
- Distribution
- Only U.S. Consignees: CO,NJ,NY, OH,PA, and WV.
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-3281-2018
- AXS Infinity LS Long Sheath:((6F/.088in)/ x 70cm GEN-10800-70, (6F/.088in)/ x 80cm GEN-10800-80, (6F/.088in)/ x 90cm GEN-10800-90) Made in Ireland, Sterile EO. The AXS Infinity LS Long Sheath system contents are: One (1
Terminated Class II Medical devices
- Recall started
- 11 April 2018
- Terminated
- 28 April 2021
- Reason
- There may be product manufactured with the outer diameter of the balloon catheter exceeding the defined specification at a customer location. If the user experiences resistance between the FlowGate and an interfacing device, the device would be removed and a second device would be used, which could potentially prolong a procedure.
- Distribution
- Nationwide
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-2569-2018
- FlowGate2 Balloon Guide Catheter, UPN 90485 (8Fx85cm size) and 90495 (8Fx95cm size)
Terminated Class II Medical devices
- Recall started
- 28 November 2017
- Terminated
- 28 April 2020
- Reason
- Stryker Neurovascular has become aware that at least 1 (one) Trevo XP Provue System was manufactured where the carton sleeve did not match the physical contents of the pack.
- Distribution
- OUS only - NL, FR, IT, DE, BE
- Initiated
- Voluntary: Firm initiated
- Recall number
- Z-0347-2018
- Trevo XP ProVue System kit containing 1) Trevo XP ProVue Retriever, 4x20mm and 2) Trevo Pro18 Microcatheter
A terminated FDA recall means the FDA has determined that all reasonable efforts to remove or correct the product have been made. What statuses mean.