Spectranetics Corporation recalls

7 recalls recorded since 2018, most recently on 10 January 2025. 5 are listed as ongoing. Status and classification are as published by the FDA.

Recalls7
Ongoing (FDA)5
Terminated or completed2
Class I (FDA)1

Ongoing Class I Medical devices

Recall started
10 January 2025
Reason
Use of Tack Endovascular system, designed to treat acute dissections of inner wall or lining of an artery by tacking damaged tissue to inner luminal surface, could result in problems with deployment and stability of device in vessel after deployment, which may cause failure to resolve dissection, migration of implant, bailout stenting, reintervention, unintended removal of tack devices, and ischemia.
Distribution
Distribution US nationwide and countries of: NL, DE, NL, AU, IT, CH, GB, and AT
Initiated
Voluntary: Firm initiated
Recall number
Z-1070-2025

Ongoing Class II Medical devices

Recall started
25 November 2024
Reason
Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted.
Distribution
U.S.: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, ILIN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, RI, SC, SD TN, TX, UT, VA, WA, WI, and WV. O.U.S.: Australia, Belgium, Brazil, China, Croatia, Cyprus, Czech Republic, Denmark, France, Ger
Initiated
Voluntary: Firm initiated
Recall number
Z-0680-2025

Ongoing Class II Medical devices

Recall started
15 November 2023
Reason
Incorrect product labeling. Exterior product box label does not match internal pouch label.
Distribution
U.S Nationwide - Worldwide Distribution: US Distribution: AL, AR, AZ, CA, CO, FL, GA, IA, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, MS, NC, NJ, NV, NY, OH, OK, PA, SC, TN, TX, UT, VA, and WA Foreign Distribution: Germany, Italy, Poland and Spain
Initiated
Voluntary: Firm initiated
Recall number
Z-0509-2024

Ongoing Class II Medical devices

Recall started
14 October 2022
Reason
Laser System may detect Error 106 or Error 108 System Failures that will cause the system to enter non-recoverable safe state. The user will not be able to proceed until the error is cleared. May result in initiation of treatment delay and/or treatment beyond initial scope and/or unable to treat patient.
Distribution
US: LA, MO, TN, CA, NC, PA, HI, AZ, CO, OK, FL, TX, MN, MI, VA, CT, NY, MD, IL, NJ, MA, KS, ME, AR, IA, IN, GA, ID, OR. OUS: DE, GB, ES, SE, IT, RS, GR, IN, FR, IL, DK, SA
Initiated
Voluntary: Firm initiated
Recall number
Z-0221-2023

Ongoing Class II Medical devices

Recall started
1 June 2022
Reason
The LAS-100 Laser system may detect an inoperable hardware component during power up, which results in an error code and the system not being operable until code is cleared.
Distribution
US: AR AZ CA CO CT FL GA HI IA IL IN KS LA MA MD ME MI MN MO NC NJ NY OK PA TN TX VA OUS: Saudi Arabia, Denmark, France, Greece, India, Italy, Netherlands, Serbia, Spain, Sweden, United Kingdom
Initiated
Voluntary: Firm initiated
Recall number
Z-1351-2022

Terminated Class II Medical devices

Recall started
31 March 2020
Terminated
31 October 2022
Reason
There is a potential for thrombus formation on balloons prepped and staged in the vasculature for long durations. All users, such as those performing lead extraction cases may not be aware of this risk. It was determined that current labeling is insufficient to ensure all potential users minimize the time the balloon remains in vasculature. If left in too long it could lead to embolization.
Distribution
US: Nationwide OUS: Australia, Austria, Belgium, Canada, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Israel, Italy, Japan, Jordan, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Norway, Poland, Portugal, Romania, Slovak
Initiated
Voluntary: Firm initiated
Recall number
Z-2143-2020

Terminated Class II Medical devices

Recall started
7 December 2018
Terminated
27 October 2020
Reason
The incorrect outer carton box was used for the product.
Distribution
Distribution was made to IA, MI, and NJ. There was government distribution. There was no military/foreign distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-0576-2020

A terminated FDA recall means the FDA has determined that all reasonable efforts to remove or correct the product have been made. What statuses mean.