SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION recalls

5 recalls recorded since 2018, most recently on 16 October 2025. 5 are listed as ongoing. Status and classification are as published by the FDA.

Recalls5
Ongoing (FDA)5
Terminated or completed0
Class I (FDA)0

Ongoing Class II Medical devices

Recall started
16 October 2025
Reason
Due to an issue (potential breakage) with the shaft for the mounting of the X-ray tube assembly that could potentially result assembly coming off the rotating shaft.
Distribution
Worldwide - U.S. Nationwide distribution including in the states of AK, AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, RI, SM, SC, SD, TN, TX, VA, WA, and WI. The countries of Dominica, Grand Bahama,
Initiated
Voluntary: Firm initiated
Recall number
Z-0499-2026

Ongoing Class II Medical devices

Recall started
6 September 2024
Reason
X-ray R/F system software with certain versions of the control board may occasionally fail to display images when switching from Fluoroscopy mode to Radiography mode, which may lead to the possibility of delay or cancellation of the examination.
Distribution
US Nationwide distribution in the states of CA, CT, MA, WV, OH, NY, IA, NE, MN, IL, FL, NC, HI, LA, MD, MT, WA, AR, TX, TN, CO.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0316-2025, Z-0317-2025

Ongoing Class II Medical devices

Recall started
6 September 2024
Reason
If digital angiography system is used with a specific catheterization table and the operator directs simultaneous movement of the table and the C-arm using direct memory, then direct memory button is released, the table may continue to move, which the operator can stop by pressing the stop button.
Distribution
US Nationwide distribution in the states of MA, IL, SC, KY, SC, OH, TN.
Initiated
Voluntary: Firm initiated
Recall number
Z-0139-2025

Ongoing Class II Medical devices

Recall started
29 January 2024
Reason
Due to capacitor manufacturing issue, their is a potential that Flat Panel Device may have abnormal display or no function.
Distribution
US Nationwide distribution in the states of OH.
Initiated
Voluntary: Firm initiated
Recall number
Z-1292-2024

Ongoing Class II Medical devices

Recall started
10 April 2023
Reason
Eight fixing bolts at the base of the X-ray ceiling tube column assembly may be loose or missing so service is required to install a cable, bracket, and label behind the bracket, indicating when service is required, to eliminate the risk of the device falling.
Distribution
U.S. Nationwide distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-2270-2023

A terminated FDA recall means the FDA has determined that all reasonable efforts to remove or correct the product have been made. What statuses mean.