GE Medical Systems Information Technologies Inc recalls

11 recalls recorded since 2018, most recently on 30 July 2026. 10 are listed as ongoing. Status and classification are as published by the FDA.

Recalls11
Ongoing (FDA)10
Terminated or completed1
Class I (FDA)0

Ongoing Class II Medical devices

Recall started
30 July 2026
Reason
Device may not resume patient monitoring for at least 3 minutes following system restart. Issue can lead to potential delay in recognition of clinically significant events.
Distribution
Worldwide - US Nationwide distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-3143-2026

Ongoing Class II Medical devices

Recall started
20 July 2026
Reason
Software issue may result in a loss of patient monitoring at the Hub and Central Viewer. In addition, all alarm settings could be reset to factory defaults following the update and will not follow the alarm settings previously configured for each patient or care area.
Distribution
US: MI, NY and Australia, Czech Republic, Finland, Germany, Italy, Netherlands, Qatar, Saudi Arabia, Switzerland, United Arab Emirates, United Kingdom.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-3038-2026, Z-3037-2026, Z-3039-2026, Z-3036-2026

Ongoing Class II Medical devices

Recall started
10 July 2026
Reason
A software vulnerability may allow unauthorized persons to gain privileged access to the device, which could result in loss of patient monitoring, missed patient alarms, and/or access to Protected Health Information (PHI).
Distribution
Worldwide - US Nationwide distribution in the state of MI, and the countries of Czech Republic, Finland, Germany, Netherland, Qatar, UAE.
Initiated
Voluntary: Firm initiated
Recall number
Z-2878-2026

Ongoing Class II Medical devices

Recall started
29 June 2026
Reason
Software issue issue with the MAC VU360 v3.0 system. After selecting the order refresh icon, an open preview or review screen might fail to close automatically after 2 minutes of inactivity. As a result, data from a previous patient may remain on the screen and could be incorrectly associated with a subsequent patient.
Distribution
Worldwide distribution - US Nationwide and the countries of Belgium, Hong Kong, Netherlands, Sweden, UK.
Initiated
Voluntary: Firm initiated
Recall number
Z-2876-2026

Ongoing Class II Medical devices

Recall started
24 April 2026
Reason
GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the CARESCAPE Central Station or CIC Pro Clinical Information Center (Central Station).
Distribution
Worldwide distribution.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2246-2026, Z-2247-2026, Z-2245-2026, Z-2244-2026, Z-2243-2026, Z-2242-2026

Ongoing Class II Medical devices

Recall started
24 April 2026
Reason
Electrical sparking may occur at the printer head. If the Electrostatic Discharge (ESD) printer brush becomes dislodged, electrical sparking at the printer head can result in charring or discoloration of thermal printer paper. Ignition of the paper could potentially result in serious thermal injury.
Distribution
Worldwide distribution - US Nationwide and the countries of Algeria, Australia, Bangladesh, Cambodia, Canada, Croatia, Denmark, Finland, France, Germany, Greece, Hong Kong, India, Indonesia, Ireland, Italy, Japan, South Korea, Lebanon, Libya, Lithuania, Malaysia, Myanmar, Netherlands, New Zealand,
Initiated
Voluntary: Firm initiated
Recall number
Z-2279-2026

Ongoing Class II Medical devices

Recall started
25 April 2025
Reason
The MUSE Administrator Account active directory or local credential could potentially be used from your local network to log into a GE HealthCare MUSE 5 system and potentially manipulate recorded patient data.
Distribution
Worldwide - US Nationwide distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-1938-2025

Ongoing Class II Medical devices

Recall started
22 April 2024
Reason
Capacitors in certain Prucka 3 Amplifiers used with CardioLab / ComboLab systems could fail resulting in transient oscillations on the display and inability to view surface and intracardiac ECG waveforms.
Distribution
Worldwide - US Nationwide distribution in the states of AK, AZ, CA, CO, FL, GA, IL, KY, MA, ME, MN, MO, NC, NJ, NY, OH, OR, PA, TN, TX, and WA. The countries of Belgium, Canada, Czech Republic, France, Germany, Ireland, Israel, Italy, Japan, Republic of Korea, and Singapore.
Initiated
Voluntary: Firm initiated
Recall number
Z-2258-2024

Ongoing Class II Medical devices

Recall started
9 April 2024
Reason
Use of the blood pressure cuffs could result in inaccurate non-invasive blood pressure measurements.
Distribution
US Nationwide distribution in the states of AL, AR, AZ, CA, FL, GA, IA, IL, IN, LA, MD, MO, MS, NC, NJ, NM, OH, PA, TN, and TX.
Initiated
Voluntary: Firm initiated
Recall number
Z-2027-2024

Ongoing Class II Medical devices

Recall started
8 August 2023
Reason
A diode on the power supply of the Prucka 3 Amplifier used with CardioLab/ComboLab systems could reach elevated temperatures and fail, then power off and become inoperable.
Distribution
Distribution was made to CA, CO, FL, GA, IL, IN, KY, MA, NC, NJ, OH, OR, PA, SC, TX, VA, and WI. There was government distribution but no military distribution. Foreign distribution was made to Canada, France, Germany, Greece, Ireland, Japan, Republic of Korea, and Romania.
Initiated
Voluntary: Firm initiated
Recall number
Z-2613-2023

Terminated Class II Medical devices

Recall started
11 January 2018
Terminated
7 July 2021
Reason
CARESCAPE Central Station (CSCS) software version 2.0.2 units may experience unexpected NO COMM (No Communication) and network communication issues after boot-up or system restart.
Distribution
Worldwide Distribution: US (nationwide) and countries of: Algeria, Australia, Austria, Canada, Costa Rica, Czech Republic, Denmark, Egypt, Finland, France, Germany, Hungary, Iceland, India, Indonesia, Iraq, Ireland, Italy, Japan, Jordan, Korea, Republic Of, Kuwait, Lebanon, Mexico, Netherlands, New
Initiated
Voluntary: Firm initiated
Recall number
Z-0487-2018