Recall Record

Blue Ash, OH, United States

Ethicon Endo-Surgery Inc recalls

13 recalls recorded since 2018, most recently on 11 September 2025. 4 are listed as ongoing. Status and classification are as published by the FDA.

Recalls13
Ongoing (FDA)4
Terminated or completed9
Class I (FDA)3

Ongoing Class II Medical devices

Recall started
11 September 2025
Reason
The devices were shipped unsterilized.
Distribution
International distribution to the countries of United Arab Emirates.
Initiated
Voluntary: Firm initiated
Recall number
Z-0147-2026

Ongoing Class I Medical devices

Recall started
22 April 2025
Reason
Firm has received an increase in reports regarding inadvertent instrument lockout during surgical procedures involving the device. If lockout occurs, the device will momentarily activate but will not cut or staple tissue, and additional steps will be required to open it and remove it from tissue. If user is unable to remove the device from the tissue, potential harms to patient include surgical delay, bleeding/hemorrhage, life threatening hemorrhage/hemorrhagic shock, and conversion to open therapy. Two adverse events received, including one patient death.
Distribution
US distribution nationwide. OUS distribution to EMEA, LATAM, APAC, and Canada.
Initiated
Voluntary: Firm initiated
Recall number
Z-1746-2025

Ongoing Class II Medical devices

Recall started
11 December 2023
Reason
There is the potential for incomplete staple line formation during the firing sequence, without most or all staples, which may lead to insufficient tissue apposition that could require surgical intervention. This may result in bleeding, prolonged surgery, or surgical delay.
Distribution
Worldwide distribution - US Nationwide and the countries of Canada and Brazil.
Initiated
Voluntary: Firm initiated
Recall number
Z-0834-2024

Ongoing Class II Medical devices

Recall started
20 July 2021
Reason
An internal component may be cracked and become lodged behind the energy button potentially resulting in continuous activation of the device, may result in burns
Distribution
Worldwide distribution - US Nationwide distribution and the countries of Austria, Argentina, Australia, Belgium, Brazil, Canada, Chile, China, Colombia, Croatia, Czechia, Denmark, Estonia, Finland, France, Germany, Greece, Guadeloupe, Hong Kong, Ireland, Israel, Italy, Japan, Jordan, Latvia, Leban
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2356-2021, Z-2355-2021

Terminated Class II Medical devices

Recall started
3 June 2021
Terminated
14 September 2022
Reason
Mislabeled: Labeled on the package as 60mm contains 45mm devices
Distribution
Worldwide distribution - US Nationwide distribution in the states of MD, WA and the countries of Belgium, China, Denmark, Estonia, France, Germany, Italy, Japan, Korea, Latvia, Lithuania, Netherlands, Poland, Portugal, Russia, Spain, Sweden, Switzerland, United Kingdom.
Initiated
Voluntary: Firm initiated
Recall number
Z-2326-2021

Terminated Class II Medical devices

Recall started
7 November 2019
Terminated
23 April 2021
Reason
A potential exists that certain LIGAMAX devices within the impacted lots may have small holes in the Tyvek lidding which could result in a breach of sterility.
Distribution
US: Nationwide International: ARGENTINA ARUBA AUSTRALIA AUSTRIA BELGIUM BRAZIL CANADA CHINA COLOMBIA DENMARK ESTONIA FINLAND FRANCE GERMANY INDIA INDONESIA IRELAND JAPAN KOREA KUWAIT MALAYSIA MEXICO NETHERLANDS NEW CALEDONIA NEW ZEALAND PANAMA PHILIPPINES PUERTO RICO QATAR SAUDI ARABIA SINGAPORE
Initiated
Voluntary: Firm initiated
Recall number
Z-0656-2020

Terminated Class I Medical devices

Recall started
3 October 2019
Terminated
3 June 2021
Reason
The staplers may contain an out of specification anvil component within the jaw of the device. This condition may lead to malformed staples, which can compromise staple line integrity. If the staple line is compromised, there is a potential risk of prolonged surgery, postoperative anastomotic leak, hemorrhage, hemorrhagic shock, additional surgical intervention, or death.
Distribution
Worldwide distribution. US Nationwide. Belgium, Brazil, Canada, Chile, Colombia, Japan, Kuwait, Saudi Arabia, and Singapore.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0200-2020, Z-0201-2020, Z-0203-2020, Z-0202-2020

Terminated Class II Medical devices

Recall started
15 May 2019
Terminated
11 June 2020
Reason
Observed reported incidence rate for harm associated with intraoperative bleeding
Distribution
Nationwide Foreign: CANADA, AUSTRALIA, BELGIUM
Initiated
Voluntary: Firm initiated
Recall numbers
Z-1890-2019, Z-1889-2019, Z-1888-2019

Completed Class I Medical devices

Recall started
11 April 2019
Reason
The staplers may have an insufficient firing stroke to break the washer and completely form staples.
Distribution
Worldwide Distribution: US (nationwide) and countries of: Argentina, Aruba, Bahrain, Bangladesh, Belgium, Bolivia, Brazil, Canada, Chile, China, Columbia, Costa Rica, Ecuador, Egypt, El Salvador, Guatemala, Honduras, India, Indonesia, Israel, Jamaica, Japan, Jordan, Korea, Kuwait, Lebanon, Malaysia,
Initiated
Voluntary: Firm initiated
Recall numbers
Z-1276-2019, Z-1278-2019, Z-1271-2019, Z-1274-2019, Z-1277-2019, Z-1267-2019, Z-1272-2019, Z-1275-2019, Z-1269-2019, Z-1268-2019, Z-1273-2019, Z-1270-2019

Terminated Class II Medical devices

Recall started
7 December 2018
Terminated
29 April 2020
Reason
Hemorrhoidal Circular Stapler may have been assembled without a washer, this may potentially cause bleeding or soft tissue injury during use as the device may not fully cut when fired
Distribution
Worldwide Distribution: US (Nationwide) and to countries of: ARGENTINA, BELGIUM, BRAZIL, CANADA, CHILE, CHINA, COLOMBIA, COSTA RICA, ECUADOR, EGYPT, INDIA, INDONESIA, JAPAN, KOREA, KUWAIT, LEBANON MEXICO, NICARAGUA, PAKISTAN, SAUDI ARABIA, SINGAPORE, TAIWAN URUGUAY and VIETNAM.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0696-2019, Z-0695-2019

Terminated Class II Medical devices

Recall started
3 May 2018
Terminated
25 November 2019
Reason
The devices may have been assembled with an internal component that may cause continuous or inadvertent activation of the device.
Distribution
Worldwide distribution - US Nationwide. The devices were distributed to the following foreign countries: Algeria, Angola, Argentina, Armenia, Australia, Austria, Belgium, Bolivia, Bosnia, Brazil, Bulgaria, Canada, Chile, China, Columbia, Costa Rica, Croatia, Czech Republic, Denmark, Ecuador, Egyp
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2049-2018, Z-2048-2018

Terminated Class II Medical devices

Recall started
26 March 2018
Terminated
8 April 2020
Reason
Use of the product with insufficient lubrication may prolong surgery due to trocar replacement. In addition, insufficient lubrication could result in a remote chance of introducing a minute particle if repeated insertions of the obturator or laparoscopic device damage the seal.
Distribution
Nationwide domestic distribution, including PR. International distribution to Saudi Arabia, United Arab Emirates, Belgium, Singapore, Taiwan, South Korea, Canada, Chile, Mexico, Japan, and Argentina.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-1889-2018, Z-1886-2018, Z-1887-2018, Z-1888-2018, Z-1885-2018

Terminated Class II Medical devices

Recall started
23 October 2017
Terminated
18 July 2019
Reason
There is a potential for the devices to create staples that do not meet formed staple height specifications which can result in malformed staples.
Distribution
China
Initiated
Voluntary: Firm initiated
Recall number
Z-0672-2018

A terminated FDA recall means the FDA has determined that all reasonable efforts to remove or correct the product have been made. What statuses mean.