40 recalls recorded since 2018, most recently on 16 February 2026. 32 are listed as ongoing. Status and classification are as published by the FDA.

Recalls40
Ongoing (FDA)32
Terminated or completed8
Class I (FDA)0

Ongoing Class II Medical devices

Recall started
16 February 2026
Reason
Due to packaging discrepancy with incorrect product size mixed up.
Distribution
GL112 Certus Medical LLC Indiana (IN) & Michigan (MI) 342-19-703 177T1057 EMPOWR 3D KNEETM INS, 3R 19MM, VE 1 MW001 Fox Medtech, LLC Colorado (CO), Wyoming (WY), Montana (MT), Counties in Nebraska 342-19-703 177T1057 EMPOWR 3D KNEETM INS, 3R 19MM, VE 1 NE190 Implant Medical Sales, Inc. New York (NY
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2700-2026, Z-2701-2026

Ongoing Class II Medical devices

Recall started
15 January 2026
Reason
Knee and Humeral socket implants contain incorrect labeling.
Distribution
US Nationwide distribution in the states of VA, TN, IL, IN, MI, CO, WY, MT, RI, MA, NJ, PA, MO, OK, LA, FL, CA.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-1458-2026, Z-1460-2026, Z-1459-2026

Ongoing Class II Medical devices

Recall started
5 January 2026
Reason
942-01-40G acetabular system package was found to contain 942-01-36H acetabular system; and several other acetabular system and knee insert devices may also have a packaging discrepancy, which may cause surgical delay to exchange devices or revision surgery.
Distribution
US: TX, IA, MI, MS, MA, RI, NJ, PA, NY, MO, OK, PR, AL, CA
Initiated
Voluntary: Firm initiated
Recall numbers
Z-1233-2026, Z-1234-2026

Ongoing Class II Medical devices

Recall started
18 July 2025
Reason
Their is a potential that the reamer may kick or bind up during or immediately prior to use.
Distribution
US Nationwide distribution in the states of AL, AZ, CA, CO, FL, HI, IA, IL, IN, KS, KY, LA, MD, ME, NE, NJ, NY, OH, PR, RI, SC, TN, TX, UT, VA, WA, WI.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2547-2025, Z-2549-2025, Z-2546-2025, Z-2548-2025

Ongoing Class II Medical devices

Recall started
9 July 2025
Reason
Knee implants contain incorrect labeling (size and/or side incorrect)
Distribution
US Nationwide distribution in the states of AL, AZ, CA, CO, FL, IA, IL, IN, KS, LA, NY, TN, TX.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2285-2025, Z-2286-2025

Ongoing Class II Medical devices

Recall started
12 June 2025
Reason
Due to packaging discrepancy with the incorrect tibial inserts/implants being packaged. Issued discovered via a customer complaint.
Distribution
RFK Medical Inc. Viriginia (VA) CE102 952-28-40E 2224A1124A EMPOWR Acetabular, Dual Mobility, Poly Bearing, ID28, OD40 1 Valor Medical Solutions South Texas (TX) CE118 952-28-40E 2224A1124A EMPOWR Acetabular, Dual Mobility, Poly Bearing, ID28, OD40 4 952-28-42F 2225A1124 EMPOWR Acetabular, Dual
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2147-2025, Z-2148-2025

Ongoing Class II Medical devices

Recall started
2 June 2025
Reason
Due to packaging discrepancy with the incorrect tibial inserts/implants being packaged. The use of this product may result in the incorrect product being selected. This could result in a revision surgery if used.
Distribution
U.S Distribution to states of: AZ, IA, ID, IL, IN, LA, MI, MO, MS, NE, NY, OK, OR, PR, SD, UT, VA, and WA
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2126-2025, Z-2125-2025

Ongoing Class II Medical devices

Recall started
28 May 2025
Reason
Package labeling for Altivate Reverse Torx Peripheral screw contains a different size then actual included product.
Distribution
At time of quarantine: RFK Medical Inc. Virginia (VA) CE102 506-04-122 5035A1018 ALTIVATE REVERSE TORX PERIPHERAL SCREW, 22mm 2 506-04-126 5037A1017 ALTIVATE REVERSE TORX PERIPHERAL SCREW, 26mm 1 Evolution Medical North Dakota (ND), Minnesota (MN), Colorado (CO), Utah (UT) C
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2008-2025, Z-2011-2025, Z-2010-2025, Z-2009-2025

Ongoing Class II Medical devices

Recall started
18 December 2024
Reason
5R 16MM knee tibial insert package may contain knee tibial insert 3R 14MM and vice versa, which may cause surgical delay to get a new product.
Distribution
US Nationwide distribution in the states of VA, MN, TX, WI, IA, IL, IN, SC, NY, MD, CA, FL, AZ, WA.
Initiated
Voluntary: Firm initiated
Recall number
Z-0766-2025

Ongoing Class II Medical devices

Recall started
10 December 2024
Reason
Knee insert package may contain an acetabular system, which may cause surgical delay to get a new product.
Distribution
US Nationwide distribution in the states of IN, KS, CA, FL, NY, TX, AL, WA.
Initiated
Voluntary: Firm initiated
Recall number
Z-0761-2025

Ongoing Class II Medical devices

Recall started
10 November 2023
Reason
Due to incorrect product/device within packaging.
Distribution
US Nationwide distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-0508-2024

Completed Class II Medical devices

Recall started
5 October 2023
Reason
Mislabeling
Distribution
US Nationwide distribution in the states of VA, TN, MN, IN, RI, ME, TX, LA, AL, FL, CA.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0625-2024, Z-0626-2024

Ongoing Class II Medical devices

Recall started
29 September 2023
Reason
Knee punch handle tip is breaking during surgery due to the lack of heat treatment, which may lead to a disruption in surgery.
Distribution
US: VA, TN, MN, TX, IL, IN, KY, OH, SC, MS, RI, ME, NJ, NY, MD, CA, KS, LA, PR, AL, FL, GA, AZ, WA
Initiated
Voluntary: Firm initiated
Recall number
Z-0258-2024

Ongoing Class II Medical devices

Recall started
25 September 2023
Reason
Two different humeral socket Insert devices were swapped during packaging, which could result in surgeons not having the correct device for surgery, which could cause a delay in surgery.
Distribution
US: MN, TX, IN, OH, SC, RI, ME, NJ, NY, KS, LA, FL, CA
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0282-2024, Z-0281-2024

Ongoing Class II Medical devices

Recall started
6 September 2023
Reason
Coating hex did not engage with the Straight Mod Hexdriver or with the Hex Head Screw Driver
Distribution
U.S.: AZ, CA, FL, IN, KS, KY, ME, MN, MS, NJ, OH, Puerto Rico, RI, SC, TN, TX, VA, and WA O.U.S.: None
Initiated
Voluntary: Firm initiated
Recall number
Z-0532-2024

Ongoing Class II Medical devices

Recall started
22 August 2023
Reason
Reverse shoulder prosthesis package that should contain 5mmx30 screws could contain incorrect 3.5mmx30 screws. Use of incorrect screws could result in surgical delay and inadequate fixation.
Distribution
US: FL, IN, WI, IA, MN, KY, NY, AZ, RI, WA, OH, SC, VA, TX. OUS: MX
Initiated
Voluntary: Firm initiated
Recall number
Z-0098-2024

Ongoing Class II Medical devices

Recall started
22 August 2023
Reason
Knee insert and acetabular system parts were swapped within inner pack prior to the product being sealed within the tray, which could result in surgeons not having the correct product for the surgery due to different anatomies (Hip vs Knee).
Distribution
US Nationwide distribution in the states of FL, CA, IN, HI, LA, MN, AZ, TX, NJ, PA, KS, TN, PR, SC, WA.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0103-2024, Z-0102-2024

Ongoing Class II Medical devices

Recall started
4 August 2023
Reason
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
Distribution
US: AL, AZ, CA, CO, FL, IL, IN, KS, KY, LA, MA, MI, MN, MO, NC, NJ, NY, OH, PA, PR, RI, SC, TX, UT, VA, WA. OUS: Sweden, Australia, France, UK, Colombia, Germany
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2603-2023, Z-2604-2023, Z-2605-2023, Z-2606-2023, Z-2607-2023

Ongoing Class II Medical devices

Recall started
28 February 2023
Reason
Patella drills are marked with incorrect diameter size of 5.6mm, when they should be 5.4mm. Porous patella overdrills are marked with incorrect diameter size of 5.4 mm, when they should be 5.6 mm. If the incorrect drill is selected during surgery, there is risk of the implant loosening, implant not properly fitting, and/or fractured bone.
Distribution
US: TX, IN, MD, CA, KS, AL, HI, WA
Initiated
Voluntary: Firm initiated
Recall number
Z-1384-2023

Ongoing Class II Medical devices

Recall started
22 December 2022
Reason
Tibial insert implant large boxes were labeled small and the small boxes were labeled large. If the incorrect labeling is identified this could lead to surgical delay and if the surgeon does not recognize the size discrepancy between the insert label and the pin label, the surgeon may implant the incorrect pin size.
Distribution
US: MN, IL, IN, NY, FL
Initiated
Voluntary: Firm initiated
Recall number
Z-1187-2023

Ongoing Class II Medical devices

Recall started
12 August 2022
Reason
Hip liner implant boxes may contain knee inserts and knee insert boxes may contain hip liner implants, which may lead to implants not being available for surgeries, which may cause delays in surgery.
Distribution
US Nationwide distribution in the states of FL, IN, IL, KY, AZ, TX.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0125-2023, Z-0126-2023

Ongoing Class II Medical devices

Recall started
5 May 2022
Reason
A right, size 8, knee tibial insert package may include a mispackaged, left ,size 4, knee tibial insert. If implanted, a risk may include leaving debris in the joint space.
Distribution
U.S. Nationwide distribution in the states of TN, MN, IL, IN, SC, MS, CA, KS.
Initiated
Voluntary: Firm initiated
Recall number
Z-1257-2022

Ongoing Class II Medical devices

Recall started
28 June 2021
Reason
Complaints have been received concerning the humeral stem failing to mate with the broach handles for a shoulder device. This could result in delay of procedure or revision surgery.
Distribution
US: AL,AR,AZ,CA,CO,FL,GA,HI,IL,IN,KY,LA,MD,ME,MI,MN,MO,MS,MT,NM,NV,NY,OH,OK,OR,PA,PR,RI,SC,TN,TX,UT,VA,WA,WV OUS: N/A
Initiated
Voluntary: Firm initiated
Recall number
Z-2331-2021

Ongoing Class II Medical devices

Recall started
12 May 2021
Reason
Packaging mixup; There is a potential that packaging identified as 12mm knee prosthesis contains 16mm knee prosthesis and 16mm knee prosthesis packaging contains 12 mm knee prosthesis.
Distribution
US: Nationwide Distribution in the states of VA, MN, TX, IL, MS, CA, KS, LA, and GA OUS: None
Initiated
Voluntary: Firm initiated
Recall numbers
Z-2103-2021, Z-2104-2021

Ongoing Class II Medical devices

Recall started
5 February 2021
Reason
Incorrect assembly of a subcomponent by a vendor and as a result, the windows provided to show the size are facing the opposite direction.
Distribution
U.S.: FL, IN, and MN O.U.S.: None
Initiated
Voluntary: Firm initiated
Recall number
Z-1524-2021

Ongoing Class II Medical devices

Recall started
9 September 2020
Reason
Due to incomplete machining a small peg remnant on the top of the dome that protrudes above the surrounding porous coating causing the cup not to seat properly.
Distribution
U.S. Nationwide distribution including in the states of CA, MN, MS, NY, SC, TN and VA.
Initiated
Voluntary: Firm initiated
Recall number
Z-0135-2021

Terminated Class II Medical devices

Recall started
31 August 2020
Terminated
19 April 2024
Reason
Product mislabeled. Use may result in a delay in surgery, stopping of surgery, and revision surgery.
Distribution
US Nationwide distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-0117-2021

Ongoing Class II Medical devices

Recall started
7 August 2020
Reason
Product may be mislabeled with the size etched onto products differing from the size information shown on patient sticker labels. Risks associated with this issue may include the Surgeon implanting the incorrect size; significant physical impairment, discomfort and/or disruption of treatment of underlying condition; and the patient experiencing dislocation resulting in revision surgery.
Distribution
Distributed in the U.S. to: VA, MN, IN, RI, PA, NY, WA, KS, OK, FL, GA and CA
Initiated
Voluntary: Firm initiated
Recall numbers
Z-3021-2020, Z-3022-2020

Ongoing Class II Medical devices

Recall started
3 August 2020
Reason
There is a potential for the retaining pin of the tibial punch handle to become loose and fall out while impacting. If undetected, there is a potential of leaving debris in the joint space.
Distribution
U.S. Nationwide distribution including in the states of VA, TN, MN, TX, IL, IN, KY, OH, SC, RI, MD, PA, NY, CA, KS, OK, AR, LA, FL, AL, GA, AZ, NV, WA, MS, ME, NV and Puerto Rico.
Initiated
Voluntary: Firm initiated
Recall number
Z-0060-2021

Ongoing Class II Medical devices

Recall started
19 June 2020
Reason
There have been issues experienced with the peg preparation steps, specifically drilling of the Femoral posterior peg. Upon drilling, the shaft portion of the drill may bind within the Posterior Peg drill guide. The extended length of the drill guide and tight tolerances to ensure accurate preparation seem to be contributing to this situation. There is a potential of a delay in surgery if this issue were to recur.
Distribution
US: AZ, CA, FL, GA, IL, IN, MI, MN, NY, TX, VA, and WA.. No OUS Consignees.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0479-2021, Z-0480-2021

Ongoing Class II Medical devices

Recall started
22 October 2019
Reason
The firm received complaints that the EMPOWR Acetabular Impactor Balls were fracturing/cracking during impaction which could cause debris to migrate or be left in the joint space.
Distribution
US Nationwide distribution including in the states of MN, VA, IL, IN, SC, N, TX, CA.
Initiated
Voluntary: Firm initiated
Recall number
Z-1929-2020

Ongoing Class II Medical devices

Recall started
4 February 2019
Reason
The firm has received reports/complaints concerning the breakage of the tips of the locking femoral Impactor. Additionally, if the impactor is not seated correctly on the implant prior to impaction, this may cause off axis loading which can increase the risk of device failure. This could cause a delay in surgery. If the tip is not seen during surgery, long term risks may include an inflammatory response, infection, and/ or pain
Distribution
CO, WA, CA, UT, CA, TN, TX, MS, MO, AR, OK, LA, MN, IL, IN, KY, OH, MI, PA, SC, FL, PR, AL, GA, NM, AZ, NV, VA, RI, MD, ME PA, NY OUS: None
Initiated
Voluntary: Firm initiated
Recall number
Z-0611-2020

Terminated Class II Medical devices

Recall started
21 September 2018
Terminated
16 September 2020
Reason
Complaints regarding loose proximal body bolts or bolts that were found through x-ray as sitting above the proximal body and not properly seated. Patient risks may include: pain, dissociation, and possible revision surgery
Distribution
US: TN, MN, TX, CO, IL, IN, OH, SC, MS, MI, RI, PA, ME, NY, WA, MO, AR, OK, LA, AL, FL, GA, UT, AZ, CA, NV,.
Initiated
Voluntary: Firm initiated
Recall number
Z-1123-2019

Ongoing Class II Medical devices

Recall started
19 September 2018
Reason
Manufacturing error, the drill bit shaft is unable to properly capture the drill bit pin. Failure of the drill bit shaft to capture the drill bit pin could result in the drill bit coming loose which could result in a delay in surgery or adverse patient reaction resulting in a revision surgery.
Distribution
US ( MS, NY, MO, OK, UT, AZ)
Initiated
Voluntary: Firm initiated
Recall number
Z-2090-2019

Ongoing Class II Medical devices

Recall started
10 July 2018
Reason
The retaining ring on the neck trials has a potential to fail interoperatively.
Distribution
Distribution was made to CA, CO, MD, MN, OH, TX, and WA. There was no foreign/military/government distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-1692-2020

Terminated Class II Medical devices

Recall started
26 June 2018
Terminated
22 August 2023
Reason
A black, aluminum oxide coating may appear on the tray after cleaning. The black, aluminum oxide coating is not biocompatible.
Distribution
US Distribution to states of; AZ, CA, CO, FL, IN, NJ, NY, NV, MI, MN, MO, OH, RI, SC, TN, TX, UT and WA and country of; Japan.
Initiated
Voluntary: Firm initiated
Recall number
Z-2600-2018

Terminated Class II Medical devices

Recall started
14 May 2018
Terminated
17 August 2020
Reason
After receipt of a product complaint for the labeling, it was determined that this device does not have FDA clearance.
Distribution
U.S. Distribution to states of: AZ, MO, MS, NY, OK, and UT; internationally to: Japan.
Initiated
Voluntary: Firm initiated
Recall number
Z-2967-2018

Terminated Class II Medical devices

Recall started
30 January 2018
Terminated
30 May 2023
Reason
Broken or missing screws and retaining clips. This may be due to screw tolerance and material strength of the trial.
Distribution
US Nationwide Distribution
Initiated
Voluntary: Firm initiated
Recall number
Z-1241-2018

Completed Class II Medical devices

Recall started
29 January 2018
Reason
It was discovered during a surgery that the design of the radius at the base of the pegs of the Anatomic Glenoid Trial (Part Numbers: 804-07-380, 804-07-420, 804-07-460, 804-07-500, and 804-07-540) is much larger on the trails than on the implants
Distribution
US Nationwide Distribution
Initiated
Voluntary: Firm initiated
Recall numbers
Z-1259-2018, Z-1260-2018, Z-1258-2018, Z-1256-2018, Z-1257-2018

Terminated Class II Medical devices

Recall started
12 December 2017
Terminated
13 June 2022
Reason
The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended.
Distribution
One medical device distributor in California.
Initiated
Voluntary: Firm initiated
Recall numbers
Z-0327-2018, Z-0326-2018, Z-0328-2018, Z-0329-2018