Carl Zeiss Meditec, Inc. recalls

4 recalls recorded since 2018, most recently on 14 January 2022. 2 are listed as ongoing. Status and classification are as published by the FDA.

Recalls4
Ongoing (FDA)2
Terminated or completed2
Class I (FDA)0

Ongoing Class II Medical devices

Recall started
14 January 2022
Reason
Optic nerve head angiography scan to be turned off due to its distribution without pre-market clearance.
Distribution
U.S Nationwide Distribution.: OH, CA, IN, AR, IA, LA, WI, OK, IL, OR, AL, KY, WY, WA, MN, NE, PA, SD, AZ, PR, TN, GA, FL, DE, NY, NH, TX, MS, MA, NV, UT, WV, ME, CO, AK, NM, KS, MO, MI, MD, ID, CT, NJ, MT, NC, VA, HI, VT, ND, SC, DC, RI
Initiated
Voluntary: Firm initiated
Recall number
Z-0723-2022

Ongoing Class II Medical devices

Recall started
8 July 2021
Reason
Due to failure to acquire pre-market clearance for its high resolution tomographic/biomicroscope imaging device (Model 6000) prior to commercializing the device.
Distribution
U.S.: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, Guam, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, Puerto Rico, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV and WY O.U.S.: N/A
Initiated
Voluntary: Firm initiated
Recall number
Z-2227-2021

Terminated Class II Medical devices

Recall started
6 December 2018
Terminated
2 February 2021
Reason
VisuMax devices with software version 2.10.13 and activated SW-Module ReLEx (SMILE) option may experience a software issue. In case of a suction loss during treatment the software allows the user to choose the option immediate restart or restart treatment. Suction loss can occur in phase 1 through phase 5. The software defect refers to Phase 2 (between 10% and 100% of lower lenticule cut) only. The software offers a flap cut, but due to the software issue it performs a cap cut instead of a flap cut if the user proceeds.
Distribution
US nationwide distribution.
Initiated
Voluntary: Firm initiated
Recall number
Z-0680-2020

Terminated Class II Medical devices

Recall started
16 October 2018
Terminated
11 June 2021
Reason
Under certain fault conditions, the existing design may expose the operator to a hazardous voltage when contacting the metal enclosure (including mounting screws) around the up/down switch.
Distribution
Worldwide distribution - US Nationwide distribution in the states of CA, TX, NY, MA, OH, PA, IA, , KY, FL, MI, IL, MD and Germany, Japan, Switzerland, France Italy, Australia, Austria, Korea, China, India, Canada, Singapore, Norway, Taiwan, Israel, UAE.
Initiated
Voluntary: Firm initiated
Recall number
Z-0770-2020

A terminated FDA recall means the FDA has determined that all reasonable efforts to remove or correct the product have been made. What statuses mean.